Gammagraphes, SENTINEL™ 1075 SCARPro

GR_QS_US_SENTINEL™ 1075 | QSA Global

Perform Small Controlled Area Radiography (SCAR) inspections near other trades, nuclear process control equipment, and critical safety systems such as visual flame detectors, to minimize the impact of RT on ongoing operations or shutdown schedules.

With the SENTINEL 1075 SCAR Pro, you can achieve up to 98% reduction in exclusion zones compared to conventional radiography techniques.

Designed, tested, and manufactured in accordance with ANSI N432-1980, ISO 3999:2004(E), IAEA TS-R-1 (2009), IAEA SSR-6 (2012), USNRC 10CFR34, USNRC 10CFR71, and USDOT 49CFR173 requirements.

 

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Avantages

  • Easy to point and shoot - very easy to use even by non-technical staff
  • Robust design for real-world industrial environments.
  • SCAR X-ray technology allows you to perform RT in close proximity to these sensor systems without the risk of interfering with process measurements or generating false alarms in safety-critical systems.
  • Minimising Exclusion Zones

Vidéo

Spécifications

SENTINELLE 1075 SCARPro GAMMA-RAY PROJECTOR SOURCE

Length

11.20 in (284 mm)

Width

6.00 in (152 mm)

Height

7.25 in (184 mm)

Maximum appliance weight

37 lb (16.8 kg)

Device capacity - Isotope

81 Ci (3 TBq) Se-75

Device shielding materials

Tungsten and stainless steel

Transport approvals

Type A in model

Overpack SENTINEL 1075A

complies with 49 CFR173, IAEA TSR-1 (2009) and IAEA SSR-6

(2012)

Weight of transport packaging

60 lbs (27.2 kg)

ASSEMBLY SPECIFICATIONS SE-75 A425-6*

Design of capsules

Dual Encapsulation

Certificate of special form

USA/0335/S-96

Sealed source and device Registration number

MA-1059-D-378-S

ANSI/ISO Source Classification

97E64515

Maximum source activity

81 Ci (3 TBq

Nuclide / Isotope

Selenium-75

Sotope Gamma Energy range

66 – 401 keV

Isotopic half-life

120 days

Isotopic output at 1 metre per Curie (37 GBq)

0.203 R/hr (2.03 mSv/hr)

Isotopic output at 1 foot per Curie (37 GBq)

2.2 R/hr (22.0 mSv/hr)

Téléchargements

BrochureAnglais832.84 KB
BrochureFrançais1.62 MB
Certificate of conformityAnglais779.67 KB
Certificate of conformityFrançais966.52 KB
Use and maintenance manualAnglais1.07 MB