Source Radio-isotopes SENTINEL™ Iridium-192

GR_QS_CZ_880-IR192

The SENTINEL Ir-192 radioisotope sources from QSA Global, Inc. are doubly encapsulated and laser welded for superior quality and safety.

Both natural and enriched iridium 192 sources are constructed using uniform-sized iridium metal discs or pellets within a welded stainless steel capsule.

The use of enriched Ir-192 produces smaller focal sizes for optimal image quality. Iridium sources are used across the industrial radiography industry to detect structural damage in metal parts.

QSA Global, Inc.'s SENTINEL Ir-192 radioisotope sources are used for industrial gamma radiography on materials such as castings, forgings, and weld defects.

Spécifications

Available for projector

Sentinel 880 series, GammaMat TI and GammaMat TSI series

Gamma energy range

206-612 keV

Steel thickness

0,39 po-3,54 po (10 mm à 90 mm)

Radioisotope output

À 1 m par Ci (37 GBq) :

0,48 R/h (4,80 mSv/h)
 

À 1 pied par Ci (37 GBq)

5,2 R/h (52,0 mSv/h)

Half-life

74 days

Certification of special forms

États-Unis/0392/S-96

États-Unis/0179/S-96

Steel operating range

0,47 po à 2,75 po (12 mm à 70 mm)

Source model

A424-9, SPEC-150 969, INC-IR100 87703

Téléchargements

Data sheetAnglais1.26 MB